Three Phase Solar + Storage Hybrid Inverters 45KW

Key Features

  • High output capacity up to 45KW.
  • Unbalance Load Acceptable Idle Consumption Search Mode, less than 100 W when Power Saver On.
  • DC input voltage 12VDC / 24VDC / 48VDC.
  • Powerful charge rate max charge current up to 450A (150A*3).
  • Intelligent commnication port RS 232, RS 485, CAN port.
  • Advanced MPPT solar charger controller Available.
  • LED + LCD Display.
  • Remote control optional (LED or LCD remote)
  • Connection mode: 3-phase 4-wire / 3-phase 3-wire.
  • AC Voltage: 3AC / N 400V / 207V.
  • DC Voltage: 48VDC.
  • Remote Control Seletable (RJ11 port / RJ45 port).
  • UItra Low THD, less than 3% under full linear load (battery low).
  • 13Vdc battery Recover Point, Dedicated for Renewable Energy Systems.
  • BTS Seletable.

 

Technical Parameters

Model 45KW
Continuous Output Power 45000W
Surge Rating (20s) 135000W
Capable of Starting Electric Motor 45HP
Unbalance Load Acceptable 100%
DC Input Voltage 48.0Vdc
Output Waveform Pure Sine wave / Same as input (Bypass mode)
Nominal Efficiency 89% (Peak)
Line Mode Efficiency >95%
Power Factor 0.9-1.2
Connection mode 3-phase 4-wire system+Gnd
Output voltage rating 3AC / N 400V / 207V
Output phase voltage 230VAC
Output Voltage Regulation ±10% RMS
Output Frequency 50/60HZ ±0.3Hz
Short Circuit Protection Yes, Current Limit Function (Fault after 60ms)
Typical transfer Time Typical 6-8ms,10ms (Max)
THD <3% Linear Loac
Nominal Input Voltage 48.0Vdc
Minimum Start Voltage 42.0Vdc / 44.0Vdc
Low Battery Alarm 42.0Vdc / 44.0Vdc
Low Battery Trip 40.0Vdc / 42.0Vdc
High Voltage Alarm & Fault 64.0Vdc
High DC Input Recovery 62.0Vdc
Low Battery Voltage Recover 52.0Vdc
Idle Consumption- Search Mode <100W when Power Saver On
Input Voltage Range Narrow: 96-132VAC / 184~253VAC;
Wide 70-135VAC70-135VAC / 140-270VAC;
Input Frequency Range Narrow: 47-55D.3Hz for 50Hz. 57-65D.3Hz for 60Hz
Wide: 40-70D.3Hz for 50Hz/60Hz
Output Voltage Same as input
Max Charge Rate 150A*3
Power Factor 0.97 MAX
Over Charge Protection Shutdown 62.8Vdc
Battery type Float Vdc
Gel U.S.A 13.7
A.G.M 1 13.4
A.G.M 2 13.7
Sealed Lead Acid 13.6
Gel Euro 13.8
Open Lead Acid 13.3
Calcium 13.6
De-sulphation 15.5 for 4hrs
Remote Control Yes. Optional LED/LCD
Input Voltage Waveform Sine wave (Grid or Generator)
Nominal Voltage 230Vac
Low Voltage Trip 184V/154Vac
Low Voltage re engage 194V/164Vac
High Voltage Trip 253V/260Vac
High Voltage re engage 243V/270Vac
Max Input AC Voltage 300Vac
Nominal Input Frequency 50Hz or 60Hz (Auto detect)
Low Freq Trip Narrow: 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz
Wide: 40±0.3Hz for 50Hz/60Hz
Low Freq re engage Narrow: 48±0.3Hzfor 50Hz, 58±0.3Hz for 60Hz Wide: 42±0.3Hz for 50Hz/60Hz
High Freq Trip Narrow: 55±0.3Hz for 50Hz, 65 ±0.3Hz for 60Hz
Wide: 70±0.3Hz for 50Hz/60Hz
High Freq re engage Narrow: 54 ±0.3Hz for 50Hz, 64 ±0.3Hz for 60Hz
Wide: 68±0.3Hz for 50Hz/60Hz
Output Short circuit protection Circuit breaker
Bypass breaker rating (230Vac) 80A
Communication methods RS32 / 458 / CAN
Display LED+LCD

Contact us and we will select for you a product that is most suitable for your production based on your production characteristics and expectations for the final product.